home *** CD-ROM | disk | FTP | other *** search
/ Technotools / Technotools (Chestnut CD-ROM)(1993).ISO / lantools / mong508 / mong508.doc < prev   
Text File  |  1989-07-17  |  3KB  |  65 lines

  1.  
  2.                      ===================================
  3.                     |  Pure Data ARCNET System Monitor  |
  4.                      ===================================
  5.  
  6.                  A utility to monitor the ARCNET system activity
  7.  
  8.                       Copyright (C) by Pure Data Ltd., 1988
  9.  
  10.  
  11.    Purpose:     This will expose the information on ARCNET system
  12.                 activity.
  13.  
  14.    Format:      MONG508.
  15.  
  16.    Output:      Display of packet/token usage on the ARCnet LAN segment
  17.                 to which the monitoring station is connected.
  18.  
  19.    Remarks:     1) It is highly recommended to run this program without
  20.                 shell loaded. This program will cause the system to hang
  21.                 if running when shell loaded.
  22.  
  23.                 2) If the program is run with shell loaded, the connection
  24.                 to the fileserver might be lost when exiting from the
  25.                 program.
  26.  
  27.    Message:     PROGRAM WILL WORK ON PDIUC508, PDI516, PDI508PLUS,
  28.                 AND PDT508
  29.                     Self-explanatory.
  30.  
  31.                 THIS PROGRAM MAY CORRUPT THE SHELL IF LOADED! PRESS Y TO
  32.                 CONTINUE :
  33.                     If the shell is actually loaded, you can either continue
  34.                 by pressing Y/y (not recommended) or exit from the shell,
  35.                 reboot the system, and then run the program.  Otherwise,
  36.                 ignore the message.
  37.  
  38.                 CARD SELF-TEST FAILED
  39.                     Before running the monitor software, a integrity test is
  40.                 performed to the interface card.  Try the program few times,
  41.                 and if the message still appears, the card is malfunctionning
  42.                 (to ensure that the card is malfunctionning, test it with
  43.                 the diagnostic utility provided on the support diskette.)
  44.  
  45.                 THE NETWORK ADDRESS OF PDI516 IS NOT SET
  46.                 THE MEMORY BASE SEGMENT OF PDI516 IS NOT SET
  47.                 THE INTERRUPT LEVEL OF PDI516 IS NOT SET
  48.                     The configuration software for PDI516 CFGI516 can be
  49.                 used to set the proper hardware parameters.
  50.  
  51.  Key Entry:     Several keys can be used to control the display screen.
  52.  
  53.                 F1  - toggle node ID display between hex and decimal.
  54.                 F2  - toggle packet count between continue and halt.
  55.                 F3  - reset packet count to zero.
  56.                 F4  - clear any node with no activity in past 4 hours.
  57.                 F10 - return back to DOS.
  58.                 Home - move the information in left window to the beginning.
  59.                 PgUp - move the information in left window 10 enties up.
  60.                 PgDn - move the information in left window 10 enties down.
  61.                 End  - move the information in left window to the end.
  62.                 CursUp - move the information in left window 1 enties up.
  63.                 CursDn - move the information in left window 1 enties down.
  64.  
  65.